91 lines
3.5 KiB
TOML
91 lines
3.5 KiB
TOML
|
# Power consumption will be calculated as follows:
|
||
|
#Idle power drain = idlePowerDrain + portal size * sizePowerDrain
|
||
|
#Interdimensional teleport power drain = travelPowerDrain + dimensionPowerDrain
|
||
|
#Same dimension teleport power drain = travelPowerDrain + (target distance)^(1/2) * distancePowerDrain
|
||
|
["Power Consumption"]
|
||
|
# If false, a portal will not require power.
|
||
|
# Allowed values: true, false - Default: true
|
||
|
requirePower = true
|
||
|
|
||
|
# How much power will a portal drain per tick when idle?
|
||
|
# Allowed range: 0 ~ 1000000 - Default: 1
|
||
|
idlePowerDrain = 1
|
||
|
|
||
|
# How much idle power does the portal drain per block of its size?
|
||
|
# Allowed range: 0.0 ~ 1000000.0 - Default: 0.5
|
||
|
sizePowerDrain = 0.5
|
||
|
|
||
|
# How much power will be drained when an entity is teleported?
|
||
|
# Allowed range: 0 ~ 1000000 - Default: 100
|
||
|
travelPowerDrain = 100
|
||
|
|
||
|
# How much energy is drained when an entity is teleported multiplied by the distance?
|
||
|
# Allowed range: 0.0 ~ 1000000.0 - Default: 0.5
|
||
|
distancePowerDrain = 0.5
|
||
|
|
||
|
# How much energy is drained when an entity is teleported to another dimension?
|
||
|
# Allowed range: 0 ~ 1000000 - Default: 400
|
||
|
dimensionPowerDrain = 400
|
||
|
|
||
|
[General]
|
||
|
# If true, a portal will require frame blocks at its corners. Previously build portals won't be affected.
|
||
|
# Allowed values: true, false - Default: false
|
||
|
requireCorners = false
|
||
|
|
||
|
# How big can the area inside a portal be? Higher numbers can impact performance when activating a portal. Previously build portals won't be affected.
|
||
|
# Allowed range: 1 ~ 2000 - Default: 400
|
||
|
maxPortalSize = 400
|
||
|
|
||
|
# Does a portal require a dimensional core for interdimensional travel? (WIP)
|
||
|
# Allowed values: true, false - Default: true
|
||
|
requireDimensionalCore = true
|
||
|
|
||
|
["Target Devices"]
|
||
|
# The maximum number of targets that can be stored in the basic target definition device.
|
||
|
# Allowed range: 1 ~ 10 - Default: 1
|
||
|
basicDeviceTargetCount = 1
|
||
|
|
||
|
# The maximum number of targets that can be stored in the advanced target definition device.
|
||
|
# Allowed range: 1 ~ 10 - Default: 5
|
||
|
advancedDeviceTargetCount = 5
|
||
|
|
||
|
["Energy Cells"]
|
||
|
# The amount of energy the portal stabilizer can store.
|
||
|
# Allowed range: 1 ~ 1000000 - Default: 5000
|
||
|
stabilizerEnergyCapacity = 5000
|
||
|
|
||
|
# The amount of energy the basic energy cell can store.
|
||
|
# Allowed range: 1 ~ 1000000 - Default: 10000
|
||
|
basicEnergyCellCapacity = 10000
|
||
|
|
||
|
# The amount of energy the advanced energy cell can store.
|
||
|
# Allowed range: 1 ~ 1000000 - Default: 25000
|
||
|
advancedEnergyCellCapacity = 25000
|
||
|
|
||
|
["Target Cells"]
|
||
|
# The number of targets the portal stabilizer can store.
|
||
|
# Allowed range: 1 ~ 20 - Default: 1
|
||
|
stabilizerTargetCapacity = 1
|
||
|
|
||
|
# The number of targets the basic target cell can store.
|
||
|
# Allowed range: 1 ~ 20 - Default: 4
|
||
|
basicTargetCellCapacity = 4
|
||
|
|
||
|
# The number of targets the advanced target cell can store.
|
||
|
# Allowed range: 1 ~ 20 - Default: 8
|
||
|
advancedTargetCellCapacity = 8
|
||
|
|
||
|
[Generators]
|
||
|
# How much energy does the coal generator generate per tick?
|
||
|
# Allowed range: 1 ~ 1000000 - Default: 10
|
||
|
coalGeneratorPower = 10
|
||
|
|
||
|
# How much energy can the coal generator store?
|
||
|
# Allowed range: 1 ~ 1000000 - Default: 5000
|
||
|
coalGeneratorCapacity = 5000
|
||
|
|
||
|
# In what area (coalGeneratorRange^3) should the coal generator send energy?
|
||
|
# Allowed range: 1 ~ 4 - Default: 2
|
||
|
coalGeneratorRange = 2
|
||
|
|